| The MPD-416S is a metal enclosed DC-DC converter that can handle both 12V and 24V DC input. The MPD-416S DC-DC converter features
four DC outputs (5V/-5V/12V/-12V), 150 watts output rating and built-in long life ball-bearing fan. The MPD-416S is designed for use in ATX personal computers, workstations or equivalent systems.
This power supply is
typically used in 12V
or 24V DC input
applications. |
| Find More |
Download full specification |
| EMAIL US FOR A QUOTE |
|
|
- 150W with 5V/-5V/12V/-12V outputs
- Wide range DC input, 12V and 24V
- Metal enclosed
- Build-in long life ball bearing FAN
- PG/PF signal available
- Wrong polarity protection, over voltage protection, over load and short circuit protection
- MTBF>140,000 hr. Mil-217F
- 2 years warranty
|
| Input Type |
DC |
| Input Voltage |
10.5V DC to +30V DC |
| Input Current |
22A at +12V DC |
| Inrush Current |
less than 10A at +12V DC |
| Outputs |
+5V |
+12V |
-12V |
-5V |
| Minimum Output Current |
1.5A |
0A |
0A |
0A |
| Rated Output Current |
16A |
4A |
1A |
1A |
| Maximum Output Current |
20A |
8A |
2A |
2A |
| Line Regulation |
1% |
1% |
1% |
1% |
| Load Regulation |
4% |
3% |
5% |
3% |
| Ripple and Noise (peak to peak) |
<1% |
<1% |
<1% |
<1% |
| Efficiency |
> 65% |
| MTBF |
140,694 hours at 50 °C |
| Power Good Signal |
When power is turned on, the power good signal will go high 100ms to 500ms after all output DC voltage are within regulation limits. |
| Power Fail Signal |
The power fail signal will go low at least 0.3ms before any of the output voltage fall below the regulation limits. |
| Overload Protection |
For some reasons the power supply fails to control itself, so the built-in over voltage protection circuit will shut down the outputs to prevent damaging the external
circuits. The trip point of crowbar circuit is around 5.7V to 7.0V. The power supply will go into hiccup mode against short circuit or over load conditions, and will auto-recovery while faulty
conditions and removed. |
| Safety |
| Designed to meet |
UL 1950 |
|
CSA No. 950-234 |
|
VDE EN 60950 |
|
| EMS |
| Designed to meet |
IEC-801-2 8KV air discharge |
|
IEC-801-3 3V/M |
|
IEC-801-4 2KV |
|
| Radiation/Conduction |
| Designed to meet |
FCC class "B" |
|
EN55022 class "B" with customer system test |
|
| Operating Temperature |
0~50 °C |
| Storage Temperature |
-40~75°C |
| Altitude (max) |
up to 10,000 ft |
| Width x Length x Height |
150x140x86.2 (mm) |
|
|
| |