| Input Type |
DC |
| Input Voltage |
18V ~ 36V DC |
| Hold Up Time |
5 ms @ 24VDC, rated load |
| Input Current |
15A@24VDC, rated load |
| Inrush Current |
60A@24VDC, one cycle at 25 °C |
| Outputs |
+5V |
+3.3V |
+12V |
-12V |
+5Vsb |
| Minimum Output Current |
1A |
0A |
0A |
0A |
0A |
| Rated Output Current |
11 A |
7.5 A |
5 A |
0.5A |
0.75A |
| Maximum Output Current |
14 A |
12 A |
10 A |
1A |
1.5A |
| Line Regulation |
±1% |
±1% |
±1% |
±1% |
±1% |
| Load Regulation |
±2% |
±4% |
±4% |
±5% |
±4% |
| Ripple and Noise (peak to peak) |
50 mV |
50 mV |
100 mV |
150 mV |
100 mV |
| Efficiency |
> 78% @ 24VDC, rated load |
| MTBF |
|
- The maximum combined total output power on the 3.3V and 5V rails is 90W.
- Initial setting accuracy is at input 24VDC and all output at 60% rated load.
|
| Power On/Off |
The power supply will be turned on when the power On/Off ping is connected to secondary GND. |
| Power Good Signal |
When power is turned on, the power good signal will go high 100 ms to 500 ms after all output DC voltages are within regulation limits. |
| Power Fail Signal |
The power fail signal will go low at least 1 ms before any of the output voltages fall below the regulation limits. |
| Short Circuit Protection |
Fully protected against short circuit. Latch off mode upon of short circuit condition. |
| Over Voltage Protection |
The over voltage protection circuit will shut down the outputs to prevent damaging external circuits if error conditions occurred. The trigger point is about 5.4~7V
at +5V. If the OVP occur, PSU cannot be recovered. |
| Over Temperature Protection |
Fully protected against output overload or over temperature. The protection point is at the temperature of the T1 over 125 °C. After the temperature of HS1 goes
down, the power supply will restart automatically. |
| Safety |
UL 60950 |
| EMS |
IEC61000-4-2, 8KV air discharge and 6KV discharge : Level 3
IEC61000-4-3, 3V/M : level 3
IEC61000-4-4, 2KV : level 3 |
Radiation
Conduction |
EN 55022/ CISPR 22 & FCC Part 15 : class B
EN 55022/ CISPR 22 & FCC Part 15 : class A |
| Operating Temperature |
0~50 °C at 100 % load, derate linearly above 50 °C by 2.5% per °C to maximum termperature of 70 °C at 50% load |
| Storage Temperature |
-20~70 °C |
| Altitude (max) |
up to 10,000 ft, operating. |
| Width x Length x Height |
198(L)x97(W)x40(H) (mm), Tolerance +/- 0.4mm |