| Input Type |
AC |
| Input Voltage |
90 ~ 264VAC |
| Hold Up Time |
16 ms @ 115VAC,
rated load |
| Input Current |
4/2A@115/230VAC,
rated load |
| Inrush Current |
30/60A@115/230VAC,
one cycle at 25 °C |
| Outputs |
+5V |
+3.3V |
+12V |
-12V |
+5Vsb |
| Minimum Output Current |
1A |
0A |
0A |
0A |
0A |
| Rated Output Current |
11 A |
7.5 A |
5 A |
0.5A |
0.75A |
| Maximum Output Current |
14 A |
12 A |
10 A |
1A |
1.5A |
| Line Regulation |
±1% |
±1% |
±1% |
±1% |
±1% |
| Load Regulation |
±2% |
±4% |
±4% |
±5% |
±4% |
| Ripple and Noise (peak to
peak) |
50 mV |
50 mV |
100 mV |
150 mV |
100 mV |
| Efficiency |
> 75% @
115VAC, rated load |
| MTBF |
na |
- The maximum combined total output power on
the 3.3V and 5V rails is 90W.
- Initial Setting Accuracy is at Input
110VAC and all output at 60% rated load.
- The total DC continuous power shall be
kept with 150W at input voltage at
110-264VAC. With input voltage
90~109VAC the total DC continuous power
shall be kept with 120W max. The maximum
total combined
output power on the +3.3V and +5V rails is
90W. On condition of with option cover, the
maximum 150W
is at 30°C environment temperature.
|
| Power On/Off |
The power supply
will be turned on when the power On/Off ping is
connected to secondary GND. |
| Power Good Signal |
When power is
turned on, the power good signal will go high
100 ms to 500 ms after all output DC voltages
are within regulation limits. |
| Power Fail Signal |
The power fail
signal will go low at least 1 ms before any of
the output voltages fall below the regulation
limits. |
| Short Circuit Protection |
Fully protected
against short circuit. Latch off mode upon of
short circuit condition. |
| Over Voltage Protection |
The over voltage
protection circuit will shut down the outputs to
prevent damaging external circuits if error
conditions occurred. The trigger point is about
5.4~6.4V at +5V. If the OVP occur, PSU cannot be
recovered. |
| Over Temperature Protection |
Fully protected
against output overload or over temperature. The
protection point is at the temperature of the
HS1 over 110 °C. After the temperature of HS1
goes down, the power supply will restart
automatically. |
| Safety |
UL 60601-1, IEC 60601-1, EN 60601-1
|
| EMS |
IEC61000-4-2:
2001, 8KV air discharge and 6KV discharge :
Level 3
IEC61000-4-3:2002, 3V/M : level 3
IEC61000-4-4:2004, 2KV line & PE : level 3
IEC61000-4-5:2001, 1KV line to line, 2KV line to
PE : level 3
IEC61000-4-6:2004, 3V/m : level 3
IEC61000-4-8:2001, 3A/m : level 3
IEC61000-4-11:2004
|
EMI
PFC |
EN
60601-1-2:2001 class B
EN61000-3-2:2000 & EN 610003-3:2001 class D |
| Operating Temperature |
0~50 °C at 100
% load, derate linearly above 50 °C by 2.5% per
°C to maximum termperature of 70 °C at 50%
load |
| Storage Temperature |
-20~70 °C |
| Altitude (max) |
up to 10,000 ft,
operating. |
| Width x Length x Height |
198(L)x97(W)x40(H)
(mm), Tolerance +/- 0.4mm |