| Input Type |
AC |
| Input Voltage |
From 90 to 130 VAC or 180 to 260 VAC, which is auto-switched by build in circuitry |
| Input Frequency |
47-63 Hz |
| Inrush Current |
40A at 115 VAC, 80A at 230 VAC |
| Outputs |
+5V |
+12V |
-12V |
-5V< |
+3.3V |
+5Vsb |
| Minimum Output Current |
0A |
0.1A |
0A |
0A |
0A |
0A |
| Rated Output Current |
25A |
10A |
0.5A |
0.5A |
8.0A |
0.72A |
| Maximum Output Current |
30A |
15A |
1A |
1A |
15A |
1.2A |
| Line Regulation |
1% |
1% |
1% |
1% |
1% |
1% |
| Load Regulation |
3% |
5% |
2% |
2% |
2% |
3% |
| Ripple and Noise (peak to peak) |
50 mV |
100 mV |
120 mV |
100 mV |
50 mV |
100 mV |
| Efficiency |
> 65% |
| MTBF |
164,375 hours at 40 °C |
| Power On/Off |
This TTL compatible signal (active low) is use to switch ON the main output. When power on is disconnected from secondary common, all outputs except +5Vsb shall turn
off. |
| Power Good Signal |
When power is turned on, the power good signal will go high 100ms to 500ms after all output DC voltages are within regulation limits. |
| Power Fail Signal |
The power fail signal will fall at least 1 ms before any of the output voltages lower the regulation limits. |
| Over Voltage Protection |
For some reason the power supply might fail to control itself, the build-in crowbar circuit will automatically shut down the outputs to avoid damaging the external
circuits. The trip point of O.V.P. circuit is around 5.7V to 7.0V. |
| Power Supply Safety Approval |
| Designed to meet |
UL 2601-1 |
|
CSA 22.2 No. 601-1 |
|
EN 60601-1 |
|
| EMS |
| IEC-801-2 |
8KV air discharge |
| IEC-801-3 |
3V/M |
| IEC-801-4 |
2KV |
| IEC-801-5 |
2KV |
|
| Radiation/Conduction |
| Desinged to meet |
FCC class "B" |
|
EN 55022 class "B" |
|
| Operating Temperature |
0~70 °C |
| Storage Temperature |
-40~75°C |
| Altitude (max) |
up to 10,000 ft |
| Width x Length x Height |
5.9 x 5.5 x 3.4 " (inch) |